Testing blinds were attached to a shortened length of the
connector assembly and placed into the test fixture. Prior
to assembly and installation both male and female couplings
were visually examined for proper tolerances, joint type and
fit up. The coupling halves were then pressed together using
the necessary jacks, shims and clamping fixtures. Figure 2
illustrates the typical set up and configuration of the fitted
24” Permalok Connector
The sealed unit was then hydrostatic pressure tested with
potable water to a pressure of 150 psi and held for 30 minutes.
The pressure was then increased to 300 psi and held for an
additional 15 minutes.
RESULTS:
No deformation or drop in pressure was noted during the testing
of the above identified connector assembly.
|